Skip to content

EdgeAppSNMPPollGroup ​

Type: Object

One poll group within an SNMP device. Either oids or walkPrefixes must be non-empty.

Fields ​

NameTypeArgsDescriptionDeprecated
handlerString!Handler name (must exist in edgeApp.handlers)
intervalMsInt!Polling cadence in milliseconds
nameString!Unique poll-group name within the device
oids[EdgeAppSNMPOIDEntry!]!Fixed-list GET OIDs (label → OID)
walkPrefixes[EdgeAppSNMPOIDEntry!]!GETBULK walk prefixes (label → sub-tree OID)