← All types
ProductionIn Input object

WorkCenterTwinSettingsInput

The whole twin settings of a work centre. Every omitted field is reset to the server default

Fields

Live shadow hysteresis bound: once DRIFTING, an operation returns to ON_TRACK only while elapsed time is at or below this quantile of the profile cell or its pace projection meets the plan. Omit for P50.

Possible values (7)
P05

5th percentile of the profile cell

P10

10th percentile of the profile cell

P25

25th percentile of the profile cell

P50

Median of the profile cell

P75

75th percentile of the profile cell

P90

90th percentile of the profile cell

P95

95th percentile of the profile cell

Live shadow: elapsed time past this quantile is DRIFTING. Omit for P90. Must not be below onTrackQuantile.

Possible values (7)
P05

5th percentile of the profile cell

P10

10th percentile of the profile cell

P25

25th percentile of the profile cell

P50

Median of the profile cell

P75

75th percentile of the profile cell

P90

90th percentile of the profile cell

P95

95th percentile of the profile cell

Live shadow: no progress point for this many minutes in SETUP or RUNNING is STALLED. At least 1. Omit for the phase cell's P50, capped by the server's maximum.

Live shadow: DOWN or ERROR for longer than this is DOWN_OVERDUE. At least 1. Omit for the profile's mean time to repair × ln 10.

Pace track: SLOWING once the forecast pace is this many percent slower than the machine's own history; STEADY again at half that. 1–100. Omit for 10.

Referenced by (1)
Exact type SDL
"""
The whole twin settings of a work centre. Every omitted field is reset to the server default
"""
input WorkCenterTwinSettingsInput {
  """
  Live shadow hysteresis bound: once DRIFTING, an operation returns to ON_TRACK only while elapsed time is at or below this quantile of the profile cell or its pace projection meets the plan. Omit for P50.
  """
  onTrackQuantile: TwinQuantile
  """
  Live shadow: elapsed time past this quantile is DRIFTING. Omit for P90. Must not be below onTrackQuantile.
  """
  driftingQuantile: TwinQuantile
  """
  Live shadow: no progress point for this many minutes in SETUP or RUNNING is STALLED. At least 1. Omit for the phase cell's P50, capped by the server's maximum.
  """
  stallMinutes: Int
  """
  Live shadow: DOWN or ERROR for longer than this is DOWN_OVERDUE. At least 1. Omit for the profile's mean time to repair × ln 10.
  """
  downOverdueMinutes: Int
  """
  Pace track: SLOWING once the forecast pace is this many percent slower than the machine's own history; STEADY again at half that. 1–100. Omit for 10.
  """
  paceSlowingPercent: Int
}