← All types
ProductionOb Object

OperationShadow

One running operation as the twin sees it right now

Fields

The running operation

jobId

JobIDNullable

Its job; null when the operation carries none

The published scenario it was started from; null when started outside the schedule

The phase the latest progress point reported

Possible values (7)
UNKNOWN

Reported status has no known operational phase

SETUP

Machine setup / makeready

RUNNING

Active production run

CLEANUP

Post-run cleanup

IDLE

Machine idle, awaiting work

MAINTENANCE

Scheduled or unscheduled maintenance

STOPPED

Machine stopped (error or manual halt)

When that phase began: the device's reported phase duration when it sends one, else the first point of the current run of this phase

The judgement for this operation

Possible values (11)
IDLE

Nothing is running on the work centre

ON_TRACK

Elapsed time and pace are within what the profile expects for this work

DRIFTING

Elapsed time is past the drifting quantile, or the pace-projected finish overshoots the plan by more than the profile's spread

STALLED

In SETUP or RUNNING with no progress point for longer than the stall window

PAUSED

The machine reported PAUSED; no judgement, the clock keeps running

DOWN

The machine's status is DOWN or ERROR

DOWN_OVERDUE

DOWN or ERROR for longer than the profile's repair expectation or the work centre's override

UNCALIBRATED

The profile has no cell for this work at any depth, so no judgement is possible

ENDED

Transition target only: the operation stopped reporting; closes its history

STEADY

Pace track only: the forecast pace is within the work centre's band of its own history

SLOWING

Pace track only: the forecast pace is slower than the machine's own history by at least twinPaceSlowingPercent; back to STEADY at half that

Phase start plus the profile cell's P10; null when uncalibrated

Phase start plus the profile cell's P50; null when uncalibrated

Phase start plus the profile cell's P90; null when uncalibrated

The planned end from the execution allocation; null when started outside the schedule

Units per minute over the recent points; null without counts

Now plus remaining units at the observed pace; null without counts

How many declared attributes the profile cell matched; 0 is the work centre's base cell

The banded attributes the cell was chosen by

Minutes since the phase started

Probability this operation still ends by its planned end, from a replay of the machine's queue; null without a plan

since

ISO8601Nullable

When the current state was entered, from the recorded transition; null when this evaluation is the first to see the state and the transition has not been written yet

Referenced by (1)
Exact type SDL
"""One running operation as the twin sees it right now"""
type OperationShadow {
  """The running operation"""
  operationId: OperationID!
  """Its job; null when the operation carries none"""
  jobId: JobID
  """
  The published scenario it was started from; null when started outside the schedule
  """
  scenarioId: ScheduleScenarioID
  """The phase the latest progress point reported"""
  phase: ProgressPhase!
  """
  When that phase began: the device's reported phase duration when it sends one, else the first point of the current run of this phase
  """
  phaseStartedAt: ISO8601!
  """The judgement for this operation"""
  state: WorkCenterTwinState!
  """Phase start plus the profile cell's P10; null when uncalibrated"""
  expectedEndP10At: ISO8601
  """Phase start plus the profile cell's P50; null when uncalibrated"""
  expectedEndP50At: ISO8601
  """Phase start plus the profile cell's P90; null when uncalibrated"""
  expectedEndP90At: ISO8601
  """
  The planned end from the execution allocation; null when started outside the schedule
  """
  plannedEndAt: ISO8601
  """Units per minute over the recent points; null without counts"""
  observedPaceUnitsPerMinute: Float
  """Now plus remaining units at the observed pace; null without counts"""
  projectedEndAt: ISO8601
  """
  How many declared attributes the profile cell matched; 0 is the work centre's base cell
  """
  evidenceDepth: Int!
  """The banded attributes the cell was chosen by"""
  attributeValues: [SimulationAttributeValueEntry!]!
  """Minutes since the phase started"""
  elapsedMinutes: Float!
  """
  Probability this operation still ends by its planned end, from a replay of the machine's queue; null without a plan
  """
  catchUpConfidence: Float
  """
  When the current state was entered, from the recorded transition; null when this evaluation is the first to see the state and the transition has not been written yet
  """
  since: ISO8601
}