← All types
ReportingOb Object

WorkCenterTwinSettings

The twin settings an author declares for a work centre. Null means the server default; the resolved values are in WorkCenterTwin.effective

Fields

Live shadow hysteresis bound: once DRIFTING, an operation returns to ON_TRACK only while elapsed time is at or below this quantile of the profile cell or its pace projection meets the plan. Null uses P50.

Possible values (7)
P05

5th percentile of the profile cell

P10

10th percentile of the profile cell

P25

25th percentile of the profile cell

P50

Median of the profile cell

P75

75th percentile of the profile cell

P90

90th percentile of the profile cell

P95

95th percentile of the profile cell

Live shadow: elapsed time past this quantile is DRIFTING. Null uses P90. Never below onTrackQuantile.

Possible values (7)
P05

5th percentile of the profile cell

P10

10th percentile of the profile cell

P25

25th percentile of the profile cell

P50

Median of the profile cell

P75

75th percentile of the profile cell

P90

90th percentile of the profile cell

P95

95th percentile of the profile cell

Live shadow: no progress point for this many minutes in SETUP or RUNNING is STALLED. Null uses the phase cell's P50, capped by the server's maximum.

Live shadow: DOWN or ERROR for longer than this is DOWN_OVERDUE. Null uses the profile's mean time to repair × ln 10.

Pace track: SLOWING once the forecast pace is this many percent slower than the machine's own history, STEADY again at half that. 1–100. Null uses 10.

Referenced by (2)
Exact type SDL
"""
The twin settings an author declares for a work centre. Null means the server default; the resolved values are in WorkCenterTwin.effective
"""
type WorkCenterTwinSettings {
  """
  Live shadow hysteresis bound: once DRIFTING, an operation returns to ON_TRACK only while elapsed time is at or below this quantile of the profile cell or its pace projection meets the plan. Null uses P50.
  """
  onTrackQuantile: TwinQuantile
  """
  Live shadow: elapsed time past this quantile is DRIFTING. Null uses P90. Never below onTrackQuantile.
  """
  driftingQuantile: TwinQuantile
  """
  Live shadow: no progress point for this many minutes in SETUP or RUNNING is STALLED. Null uses the phase cell's P50, capped by the server's maximum.
  """
  stallMinutes: Int
  """
  Live shadow: DOWN or ERROR for longer than this is DOWN_OVERDUE. Null uses the profile's mean time to repair × ln 10.
  """
  downOverdueMinutes: Int
  """
  Pace track: SLOWING once the forecast pace is this many percent slower than the machine's own history, STEADY again at half that. 1–100. Null uses 10.
  """
  paceSlowingPercent: Int
}