EdgeAppModbusRead
One typed Modbus read
Fields
Surfaces as params.values.
Function code family
Possible values (4)
HOLDINGHolding registers (FC03/FC06/FC16)
INPUTInput registers (FC04, read-only)
COILSCoils (FC01/FC05/FC15)
DISCRETEDiscrete inputs (FC02, read-only)
Starting address (0...65535)
Number of registers/coils
Decoding type
Possible values (7)
UINT1616-bit unsigned (1 register)
INT1616-bit signed (1 register)
UINT3232-bit unsigned (2 registers)
INT3232-bit signed (2 registers)
FLOAT3232-bit float (2 registers)
BOOLSingle bit (coil or discrete)
RAWRaw register/coil array — handler decodes
Optional multiplier for numeric types
Word order for multi-register types (default high)
Possible values (2)
HIGHHigh word first (default)
LOWLow word first
Byte order for multi-register types (default big)
Possible values (2)
BIGBig-endian (default)
LITTLELittle-endian
Referenced by (1)
Exact type SDL
"""One typed Modbus read"""
type EdgeAppModbusRead {
"""Surfaces as params.values.<label>"""
label: String!
"""Function code family"""
function: EdgeAppModbusFunction!
"""Starting address (0...65535)"""
address: Int!
"""Number of registers/coils"""
quantity: Int!
"""Decoding type"""
type: EdgeAppModbusReadType!
"""Optional multiplier for numeric types"""
scale: Float
"""Word order for multi-register types (default high)"""
wordOrder: EdgeAppModbusWordOrder
"""Byte order for multi-register types (default big)"""
byteOrder: EdgeAppModbusByteOrder
}